{"id":55,"date":"2020-11-27T15:10:32","date_gmt":"2020-11-27T15:10:32","guid":{"rendered":"http:\/\/truflo.in\/?page_id=55"},"modified":"2021-01-03T07:38:00","modified_gmt":"2021-01-03T07:38:00","slug":"softwares","status":"publish","type":"page","link":"https:\/\/truflo.in\/index.php\/softwares\/","title":{"rendered":"Software"},"content":{"rendered":"\n<p>A seemingly insignificant  error in measurement systems  may cost you  millions!!!.  Truflo offers you a complete measurement validation and calculation package for offline as well as online measurement validations. <\/p>\n\n\n\n<p class=\"has-white-color has-text-color has-background has-medium-font-size\" style=\"background-color:#0c00ff\"><span class=\"has-inline-color has-white-color\">Truflo Measurement Suite<\/span>&#8211;<sup>Offline<\/sup><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Offline Version:<\/strong><\/p>\n\n\n\n<p>Truflo provides a comprehensive package , a must have toolkit for measurement specialists\/engineers, including all flow measurement related calculations for Fiscal\/Custody Transfer measurements in Oil &amp; Gas Industries. Calculations for metering systems based on different measurement principles  like Ultrasonic Meters, Turbine Meters, Rotary Positive displacement Meters  , Orifice Meters as per applicable AGA,ISO,GPA and API standards. These Include:<\/p>\n\n\n\n<p>AGA-3 Calculations for Orifice based flow measurement systems<\/p>\n\n\n\n<p>AGA-7 Calculations for Turbine\/ RPD\/ USM on pulse  based flow measurement systems<\/p>\n\n\n\n<p>AGA-9 Calculations for Ultrasonic Meters<\/p>\n\n\n\n<p>AGA-8 Calculations for thermodynamic properties for gas measurement s like compressibility factors and other properties<\/p>\n\n\n\n<p>AGA-10 Calculations for Speed of Sound for Ultrasonic Meters . Calculations are now available as AGA 8 PART-I, post revision of the standard<\/p>\n\n\n\n<p>AGA5 Energy Measurement<\/p>\n\n\n\n<p>ISO 6976 Calculations for calorific values and other properties<\/p>\n\n\n\n<p>GPA 2172 Calculations for calorific values and other properties<\/p>\n\n\n\n<p>These are only a set of most frequent used calculations in any gas measurement system. the package offers a set of various other calculation and other measurement utilities.<\/p>\n\n\n\n<p>Truflo Measurement Suite -line is available on a licensed basis. All calculations  are regularly checked for accuracy and updated to ensure continued compliance with the latest industry standards and regulations. Truflo Measurement Suit  gives  the requisite  confidence to all parties involved in fiscal transactions.<\/p>\n\n\n\n<figure class=\"wp-block-image is-resized\"><a href=\"https:\/\/truflo.in\/index.php\/contact\/\"><img loading=\"lazy\" src=\"http:\/\/www.kelton.co.uk\/uploads\/Contact%20Us%20for%20a%20Quote.png\" alt=\"Contact Us Button\" width=\"282\" height=\"72\"\/><\/a><\/figure>\n\n\n\n<p class=\"has-white-color has-text-color has-background has-medium-font-size\" style=\"background-color:#0c00ff\"><span class=\"has-inline-color has-white-color\">Truflo Virtual Flow Computation with Digital Twin<\/span><sup>online<\/sup><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Online Version:<\/strong><\/p>\n\n\n\n<p><em>Recognizing the&nbsp; imminent need for development of online validation, audit &nbsp;and diagnostic systems which track ,monitor and predict the health of the gas metering equipment\/instruments &nbsp;on their own without intervention of the operators and keep the operator updated in case of any deviations from normal course of operation , virtual flow computers with Digital Twin has been created to  gain insight about the equipment operational behavior and prediction of condition of equipment. The solution uses information from relevant standards like : <strong>ISO, GPA ,AGA ,AP<\/strong>I and other relevant techniques like&nbsp; Control charts etc. Operational alerts in case of any Mis- Measurements in terms of volumetric or energy or mass flow with quantification of errors with probable cause and rectification measures are provided. Thus the need for frequent audits, validations and manual generation of records for compliances is done online without intervention of operator. This helps in enhancing the confidence in custody transfer measurement system and thus addressing <strong>LAUF (Lost and Unaccounted For) <\/strong>accounting and improving <strong>gas balancing and reconciliation <\/strong><\/em>.<\/p>\n\n\n\n<figure class=\"wp-block-gallery columns-1 is-cropped\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><img loading=\"lazy\" width=\"1024\" height=\"576\" src=\"http:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC-1024x576.jpg\" alt=\"\" data-id=\"93\" data-full-url=\"http:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC.jpg\" data-link=\"http:\/\/truflo.in\/index.php\/softwares\/vfc\/\" class=\"wp-image-93\" srcset=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC-1024x576.jpg 1024w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC-300x169.jpg 300w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC-768x432.jpg 768w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC-1200x675.jpg 1200w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/VFC.jpg 1366w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/figure><\/li><\/ul><\/figure>\n\n\n\n<p><strong><span class=\"has-inline-color has-luminous-vivid-orange-color\">Raise confidence in pipeline Integrity and leak detection :<\/span><\/strong><\/p>\n\n\n\n<p><em>Pipeline industry deploys various pipeline leak detection system using Mass Balancing or Pressure Wave or other principles. However, the accuracy of the leak detection\u00a0 often depends upon the accuracy of the associated instrumentation system like flow, pressure ,temperature and gas quality parameters measurement. Being electronic devices it is always possible to observe drift in these instruments which may\u00a0 introduce a bias in the measurement and thus the accuracy of leak detection is impacted. This online system  validates the entire measurement system including primary meter and secondary measurement devices for any mis measurement with identification of the possible cause of drift\/inaccuracy with recommended solutions to reinstate the measurement accuracy . Thus any disputes or arbitration with customer and suppliers can be avoided using the system.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/truflo.in\/index.php\/contact\/\"><img src=\"http:\/\/www.kelton.co.uk\/uploads\/Contact%20Us%20for%20a%20Quote.png\" alt=\"Contact Us Button\"\/><\/a><\/figure>\n\n\n\n<p class=\"has-white-color has-text-color has-background has-medium-font-size\" style=\"background-color:#0c00ff\"><span class=\"has-inline-color has-white-color\">Truflo GC Diagnostic Package<\/span><\/p>\n\n\n\n<p><strong><span class=\"has-inline-color has-luminous-vivid-orange-color\">Gas Chromatograph Diagnostics Package:<\/span><\/strong><\/p>\n\n\n\n<p>Inspection of the calibration data generated can give an indication as to whether the equipment and the methods are working satisfactorily. Data generated during the calibration of online gas chromatograph are captured and further analyzed based on the GC&nbsp; design and configuration of columns and valves. System is able to capture any deterioration of the standard calibration gas, operator mistakes while entering the calibration blend in GC configuration, Valve malfunctions etc. System uses methods as described in various applicable standards like ISO 6974, GPA 2198 and GC &nbsp;manufactures manuals.<\/p>\n\n\n\n<figure class=\"wp-block-gallery columns-2 is-cropped\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><img loading=\"lazy\" width=\"1024\" height=\"576\" src=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1-1024x576.jpg\" alt=\"\" data-id=\"94\" data-full-url=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1.jpg\" data-link=\"https:\/\/truflo.in\/index.php\/softwares\/gc-dia-1\/\" class=\"wp-image-94\" srcset=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1-1024x576.jpg 1024w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1-300x169.jpg 300w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1-768x432.jpg 768w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1-1200x675.jpg 1200w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/GC-DIa-1.jpg 1366w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/figure><\/li><li class=\"blocks-gallery-item\"><figure><img loading=\"lazy\" width=\"1024\" height=\"576\" src=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2-1024x576.jpg\" alt=\"\" data-id=\"95\" data-full-url=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2.jpg\" data-link=\"https:\/\/truflo.in\/index.php\/softwares\/gc-dia-2\/\" class=\"wp-image-95\" srcset=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2-1024x576.jpg 1024w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2-300x169.jpg 300w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2-768x432.jpg 768w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2-1200x675.jpg 1200w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/gc-dia-2.jpg 1366w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/figure><\/li><\/ul><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/truflo.in\/index.php\/contact\/\"><img src=\"http:\/\/www.kelton.co.uk\/uploads\/Contact%20Us%20for%20a%20Quote.png\" alt=\"Contact Us Button\"\/><\/a><figcaption><a href=\"https:\/\/truflo.in\/index.php\/contact\/\" data-type=\"page\" data-id=\"14\">Contact<\/a><\/figcaption><\/figure>\n\n\n\n<p class=\"has-white-color has-text-color has-background has-medium-font-size\" style=\"background-color:#0c00ff\"><span class=\"has-inline-color has-white-color\">Truflo USM  Diagnostic Package<\/span><\/p>\n\n\n\n<p><span class=\"has-inline-color has-luminous-vivid-orange-color\" style=\"\"><b>USM Diagnostics Package:<\/b><\/span><\/p>\n\n\n\n<p>With the advancement of technology USM meter are becoming smarter day by day. These meters offers various diagnostic parameters which are not only indicative of the health of the meter itself but also help in identifying process related problems like flow profile distortion due to installation problems or incorrect installation operations like partial close valves or valve noise. Generally USM meters have&nbsp; multiple paths. The Software acquires relevant raw data at very high frequency &nbsp;from USM meter and processes the diagnostic parameters which are monitored online and also stored for future retrieval and further extension to other third party applications. These include Parameters like Path Performance, SOS Validations as per AGA10\/AGA8, Velocity Profile and spread, SOS spread, Automatic GAIN Control (AGC) parameters, Signal To Noise (SNR) ratio, Profile factors, Asymmetry and cross flow etc. <\/p>\n\n\n\n<figure class=\"wp-block-gallery columns-1 is-cropped\"><ul class=\"blocks-gallery-grid\"><li class=\"blocks-gallery-item\"><figure><img loading=\"lazy\" width=\"1024\" height=\"576\" src=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS-1024x576.jpg\" alt=\"\" data-id=\"96\" data-full-url=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS.jpg\" data-link=\"https:\/\/truflo.in\/index.php\/softwares\/usm-diagnostics\/\" class=\"wp-image-96\" srcset=\"https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS-1024x576.jpg 1024w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS-300x169.jpg 300w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS-768x432.jpg 768w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS-1200x675.jpg 1200w, https:\/\/truflo.in\/wp-content\/uploads\/2021\/01\/USM-DIAGNOSTICS.jpg 1366w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/figure><\/li><\/ul><\/figure>\n\n\n\n<p>Truflo provides one stop solution for all your measurement needs.  <\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/truflo.in\/index.php\/contact\/\"><img src=\"http:\/\/www.kelton.co.uk\/uploads\/Contact%20Us%20for%20a%20Quote.png\" alt=\"Contact Us Button\"\/><\/a><\/figure>\n\n\n\n<p class=\"has-medium-font-size\"><em><strong><span class=\"has-inline-color has-vivid-cyan-blue-color\">Gas Measurements&#8230;&#8230;.Look no further&#8230;&#8230;<\/span><\/strong><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A seemingly insignificant error in measurement systems may cost you millions!!!. Truflo offers you a complete measurement validation and calculation package for offline as well as online measurement validations. Truflo Measurement Suite&#8211;Offline Offline Version: Truflo provides a comprehensive package , a must have toolkit for measurement specialists\/engineers, including all flow measurement related calculations for Fiscal\/Custody Transfer measurements in Oil &amp; Gas Industries. Calculations for metering systems based on different measurement principles like Ultrasonic Meters, Turbine Meters, Rotary Positive displacement Meters &hellip; <a href=\"https:\/\/truflo.in\/index.php\/softwares\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Software&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/pages\/55"}],"collection":[{"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/comments?post=55"}],"version-history":[{"count":4,"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/pages\/55\/revisions"}],"predecessor-version":[{"id":104,"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/pages\/55\/revisions\/104"}],"wp:attachment":[{"href":"https:\/\/truflo.in\/index.php\/wp-json\/wp\/v2\/media?parent=55"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}